Click here to Skip to main content
15,892,005 members
Everything / DB2

DB2

DB2

Great Reads

by Martin Vorbrodt
SQL database access
by Phani Krishna Kollapur Gandla
How to solve performance issues in data migration to SQL Server.
by ASP.NET Community
Providers factory provides us indepandent database access where we can connect to any database sources(SQLServer,DB2,Oracle,MS-Access).Provider
by YawerIqbal
Last week in a meeting client explained requirement: “.. we receive emails in a mail box, and we manually create contacts in CRM using sender name and address for further processing, we want to automate this.. .

Latest Articles

by YawerIqbal
Last week in a meeting client explained requirement: “.. we receive emails in a mail box, and we manually create contacts in CRM using sender name and address for further processing, we want to automate this.. .
by Martin Vorbrodt
SQL database access
by Bryan Kowalchuk
The two most common database lookup table patterns are examined
by ASP.NET Community
Providers factory provides us indepandent database access where we can connect to any database sources(SQLServer,DB2,Oracle,MS-Access).Provider

All Articles

Sort by Title

DB2 

12 Oct 2017 by NekoNao
I was able to connect to iSeries Access ODBC Driver using ASP.Net. Simple where clause and select is working but when I have encountered the WHERE IN CLAUSE it throws back error. My code is like this below: Dim sql as string ="Select * from table where column in (?)" cmd.Parameters.Add("",...
12 Oct 2017 by Richard Deeming
Something like this: Dim sql As New StringBuilder("SELECT * FROM table WHERE column IN (") Dim parts As String() = txt_Param.Text.Split(","c) For i As Integer = 0 To parts.Length - 1 cmd.Parameters.Add("", Odbc.OdbcType.Char).Value = parts(i) If i 0 Then sql.Append(", ") ...
20 Oct 2016 by Bryan Kowalchuk
The two most common database lookup table patterns are examined
9 May 2015 by jinesh sam
Hi Friends,My requirement is to validate db2 rows.I will give a brief description on what my project is.I need to validate the bill generated on previous day based on some formulas.I have only Read access to DB2.As part of testing i fetch all the previous date records(which is considered as...
9 May 2015 by OriginalGriff
"Can i use threading?"We can't tell you: the problem is that we have no idea what your calculations are trying to do. If they are independent, then possibly you can use threading within individual steps, but to my mind Step 3 depends on Step 2 completing, Step 4 depends on Step 3 completing,...
13 Dec 2013 by gettgotcha
I have a CSV file which has some amount of data for which we are planning to move the data to a DB2 table (its only one time job). So I was planning of something using BulkInsert (sorry if I am wrong as I don't have any knowledge of DB2) through C# code. So please suggest how to write the code...
13 Dec 2013 by bowlturner
Since this is a one time job looping through might just be the easiest way to do it.However, with Oracle we have SQLLoader which takes a control file and the data file and will do the work for you. I looked and DB2 has 2 tools that appear to be similar DB2 LOAD and DB2 IMPORTHere's...
15 Apr 2016 by Kedarnath M S
How can I convert the bellow code to SQL Query(Stored Procedure) ?string[] strORCarriers = IW.GetORCarriers();if (strORCarriers.Length != 0) { for (int i = 0; i
15 Apr 2016 by Richard Deeming
If you want to concatenate string values from multiple rows in SQL, use one of the methods described in this artice:Concatenating Row Values in Transact-SQL[^]For example:SELECT p1.CategoryId, STUFF( ( SELECT ',' + ProductName FROM...
20 Apr 2015 by Member 11628812
We are upgrading my DB2 8.1 on Windows server 2000 to DB2 9.7 on Windows server 2012 R2.There is one C++ dll used to write log files which works file with DB2 8.1 but doent produce even log file on Windows server 2012 R2. Further I dont have source of that dll.Possible cause: 32 bit C++...
21 Apr 2015 by Member 11629203
32 bit software will not work on 64bit machine. Please download the 64 bit application at first. There are some article at "c programming" : www.cprogramming-bd.com
30 Nov 2013 by Lajpat Kurdiya
Hi FriendsI want to know how to implement security over the column and row in DB2 database.Many thanks in advance.RegardsLajpat Kurdiya
30 Nov 2013 by CHill60
Have a look at this IBM Article practical guide to implementing row and column access control in DB2 [^]
26 Jul 2013 by shakilajannat
how can i comparing data from two database table using vb.code
15 Oct 2012 by Anele Ngqandu
HiI am trying to connect DB2 database in my application I get this error:"ERROR [42704] [IBM][DB2/NT] SQL0204N "DB2ADMIN.TBL_USER" is an undefined name."Please help me on solving this error. string connString = "Database=dbName;userID=usrname;password=pass...
15 Oct 2012 by Manfred Rudolf Bihy
I'd guess that the table does in user DB2ADMIN's schema. Try something like this:DB2Command cmd = new DB2Command("SELECT * FROM dbo.TBL_USER", con);Where dbo shall be substituted for the schema your table TBL_USER is really in.Regards,— ManfredMight want to read some...
6 Dec 2018 by ashu_1july
can you please help me to how to convert below sql server function to db2 format. CREATE FUNCTION [dbo].[GetKeyStructureXml] ( @pf_wkstn_oid_sh smallint, ) RETURNS varchar(max) AS BEGIN DECLARE @RtKeys varchar(Max) set @RtKeys = (SELECT rt.rbase_field_name, ...
6 Dec 2018 by CHill60
DB2 is essentially the same as Oracle so try the following references: ...for XML Auto equivalent in PL\SQL? | Oracle Community[^] Generating XML Data from the Database[^] ORACLE-BASE - SQL/XML (SQLX) : Generating XML using SQL[^] Of course there is nothing like the actual documentation -...
23 Oct 2013 by Viritha Reddy
Hi, how to convert column values into rows in winsql. If anyone knows solution please share with me.Thanks In Advance.
19 Mar 2014 by Member 9353131
How to create a temporary table in stored procedure in db2?Below is my stored procedure and i'm getting error while executing this Procedure.DECLARE RTIMID_MATCH INTEGER;DECLARE PARAMS_VALUE VARCHAR(2500);DECLARE tmp_param varchar(500); DECLARE tmp_seperated_param varchar(500); DECLARE...
23 Mar 2014 by CHill60
Look at the error - it's not even hinting that you are creating a temporary table never mind incorrectly, so what you are really asking is "how can I solve this error".I haven't got DB2 (or Oracle) to hand at the moment so I am going to walk you through a method of solving the problem for...
15 Apr 2019 by YawerIqbal
Last week in a meeting client explained requirement: “.. we receive emails in a mail box, and we manually create contacts in CRM using sender name and address for further processing, we want to automate this.. .
8 Nov 2011 by Manivannan Dheena
Hi, I need to create a sample database in db2, when i logged in as a standard power user in my windows machine.Syntax: CREATE DATABASE TESTDB3 AUTOMATIC STORAGE YESBut this works when i run as a admin user, But same not allowing me to create db as a power user, Also i...
8 Nov 2011 by Mehdi Gholam
Use this : db2 CONNECT TO database USER userID USING password
13 Nov 2011 by vinothmkgfslppy
I have one doubt in db2 database for get ddl script for database object. I have get one command in ibm web site db2look -d DATABASE -t "TABLENAME" -a -e -l -x -c ; but this command not excute in command editor.How to get existing table ddl script in db2 database.
7 Oct 2011 by davidshenba
Conversion of 7 digit integer date format to SQL date format
27 Aug 2013 by Member 9353131
Hi frnz,I have created the following stored procedureCREATE or REPLACE PROCEDURE RTIMD.IALERT_PROC ( IN usr_name VARCHAR(20) DEFAULT '', IN IN_RTIM_ID VARCHAR(25) default '', IN api_method VARCHAR(25) DEFAULT '', IN params VARCHAR(500) default '', IN application_name VARCHAR(20)...
2 Feb 2017 by Menci Lucio
Hi,I recently updated my db2 engine in my test machine from 9.7 to 10.5.I wasn't able to have execute plains. It says me:com.ibm.db2.jcc.SqlException: The Explain table "db2inst.EXPLAIN_INSTANCE", column "25" does not have the proper definition or is missing. SQLCODE=-220,...
2 Feb 2017 by Menci Lucio
FOUND!The problem was the table and not the file was in old version. This DDL creates the tables, without droping them before. The tables were created in 9.7. Dropped tables, runned file, now all runs well.
31 May 2017 by Menci Lucio
Hi, I wrote a lot of parametrized queries where parameters are inserted by the user. If the user inserts strings longer than the field where parametrized value is referring to, DB2 throws a SQL0302N error. There is a way to avoid it? Example: Create Table Foo (Code Char(3) Not Null, Descr...
21 Oct 2015 by Menci Lucio
Hi,Hi have DB2 9.7.200.358/Windows 7 Ult SP1. After an Alter Table Add Column command, the DB engine retrieves the error in the object for any select into that table. I restarted the DB, I restarted windows, but the issue remains.I noted this:SELECT * FROM SYSIBMADM.ADMINTABINFO where...
11 Dec 2011 by Manivannan Dheena
Hi, i am running a delete statement, which deltes more than 10000 records in my db2 database table, in that time, when i execute it throws me error, saying "transaction log is full"my db2 config file details are, Group commit count (MINCOMMIT) = 1Percent log...
11 Feb 2014 by Walterls
Please refer to this thread: http://stackoverflow.com/questions/996403/disable-transaction-log
14 Jan 2016 by DoomMaker79
Dear All,I'm creating a winform app in c#, that connects to DB2 database server. Of course I have installed every required db2 extensions on the developer machine, that's why it works on the developer machine.But after I deploying the app with ClickOnce and starting on the client...
14 Jan 2016 by Richard Deeming
The 0x8007007E error means you are trying to load a 32-bit DLL in a 64-bit program, or vice-versa.Assuming the DLL is 32-bit, change your program's target platform from "AnyCPU" to "x86" and recompile.
9 Jul 2021 by Mirec7
Next to the good hint from Richard Deeming, if you still run into problems with DllNotFoundException: Unable to load DLL 'db2app.dll', I have a solution here, which helped me 2 days ago: My problem was with the NuGet: IBM.Data.DB.Provider...
14 Nov 2011 by vinothmkgfslppy
How to get seuqence and packages create script from db2 database excute through command editor. Please reply for which query .....
10 May 2022 by Rogue258
I have a table_A which has names and delivery dates as follows Name Del_dt Mark 2022-04-01 Mark 2022-04-03 Mark 2022-04-05 Mark 2022-04-07 Mark 2022-04-09 Dave 2022-04-02 Dave 2022-04-04 Dave 2022-04-06 Dave 2022-04-08 Dave 2022-04-10 and so...
10 May 2022 by Maciej Los
Not sure what you mean by "cumulative counts"... I'd suggest to use WITH clause[^]: WITH CTE(Cust_Name, og_date, cul_cnt) AS ( SELECT Name, Del_dt, COUNT(*) FROM YourTable WHERE Del_dt BETWEEN '2022-04-07' AND '2022-04-10' GROUP BY...
23 Aug 2012 by Smart003
tell me about db2 and difference b/w db&db2
23 Aug 2012 by Mehdi Gholam
DB is a generic term for a database/database engine/database server.DB2 is an IBM database product.
24 Aug 2012 by Smart003
db2 is a the extension of dband we may receive more benifits from the db2 compare with db
30 Oct 2015 by arslan iub
I want to know that have Views some impact on performance of database means that if we use Views instead of table directly in our queries, it increase the performance while direct use of table in queries maximize IO operation on server and cause of low performance.Guide me please
30 Oct 2015 by phil.o
This SO post is quite informative about that matter:SO: Is a view faster than a simple query?[^]Hope this helps.
30 Oct 2015 by CHill60
This is not really a topic for a Quick answers forum. I suggest you do some research, and here is an article to get you started - "Poor Little Misunderstood Views"[^] from SqlServerCentralThere is also a longer discussion here[^]
3 Mar 2021 by Abhishek Pant
What is fenced User-ID of a DB2 instance?And also want some proper purpose of it as I got this linkHow to determine fenced User-ID of a DB2 instance[^]saying "The purpose of fenced user id is to protect DB2 from untested or malicious code from the external stored procedures, user defined...
10 Jan 2013 by Wendelius
When a fenced stored procedure is run, it can use a fenced user to execute it in order to have less privileges for example at operating system level. Otherwise the fenced stored procedure is run by the same user account that is running DB2 agent.In other words, by using a fenced user, you...
3 Mar 2021 by Member 15089602
You can first login into the instance and then run the below command: cat /home/INSTANCENAME/sqllib/ctrl/.fencedID after which you can also run the below command to if db2fmp process is running. ps -ef | grep -i db2fmp and then run: db2pd -fmp
29 Sep 2015 by sudevsu
Hello Experts,I have a Stored procedure that returns a dataset in VB.NET for a Grid display. Now the requirement is little tough. I have got one more stored procedure that should be called on each row of the returned Dataset. I wanted to know how can we do it database instead of...
24 Sep 2015 by 1310s
actually ,calling sp on each single row will cause performance degrade surely.better to change the approach instead of going with sp.
16 Jul 2012 by Dattatrya Moin 11
Hi, I am using DB2BulkCopy to copy data to database. But in some exceptional cases column type mismatching happens and it is giving the problem "Error Code = 22005 (Error in assignment)" exception and after some time program is getting hang and giving Function Sequence Error. How to avoid...
28 Dec 2015 by Member 10420430
I am getting exception on entities.ABCTable.Where(abcTable => abcTable.Comment.ToUpper() == value.ToUpper()).FirstOrDefault()Here, Column 'Comment' length is varchar 3500 and input value length is 300. But don't know why getting this exception :"ERROR [22001] [IBM] CLI0109E ...
28 Dec 2015 by Maciej Los
Follow this: PJ35283: STRING DATA RIGHT TRUNCATION ERROR AFTER MODIFYING STRING SIZE O F A DATA FIELD IN DB2 DATABASE[^] and this: String data right truncation when starting the Commerce Acceleartor tool[^] and finally this: Build Forge error: CLI0109E String data right truncation. SQLSTATE=22001[^]
19 Apr 2013 by Member 10000741
i had developed a website using db2 and java jsp servlets and i want to host the website how to d this plz help me
18 May 2017 by zamzam_301
i have DB2 database i connect to it by vb.net all thimg is ok but when i want to search for an Employee by by name it is not work here code it work if gname.text is clear show all emplyee What I have tried: Dim s As String = "SELECT GEMPNO, GNAME, GTERM FROM qgpl.testz where gname like '% "...
18 May 2017 by zamzam_301
'this code solve my problem Dim s As String = "SELECT EMPNO, NAME FROM lib.file " Dim selectCMD As OdbcCommand = New OdbcCommand(s, MyODBCConnection) 'start the Read loop Dim Adapter As OdbcDataAdapter = New OdbcDataAdapter(selectCMD.CommandText, MyODBCConnection) Dim ds As DataSet =...
19 Mar 2015 by jinesh sam
Hi friends,I need to append one character to DB2 column in select QuerySELECT KEY_TMS FROM TCLT_BILLi need to append one character to the select query Suppose the result is abcdi need to get as abcd-i try Concat method its not working+ symbol is not working in...
19 Mar 2015 by CHill60
If SELECT CONCAT(KEY_TMS, '-') FROM TCLT_BILL;does not work then try SELECT KEY_TMS || '-' FROM TCLT_BILL;If that also doesn't work then it may be the datatype used for KEY_TMS, try SELECT CONCAT(CAST(KEY_TMS AS VARCHAR2(50)), '-') FROM TCLT_BILL;
29 Jan 2013 by ujju.1
Hi experts. My aim is to call through ASP a CL program (in AS400) and return the result.I have fount a nice article about this at Calling AS/400 (AS400) RPG Programs From ASP.NET[^] . But it does not elaborates anything regarding CL program.As given in the article, I have created the...
29 Jan 2013 by _Maxxx_
It's been far too long since I counted RPG and CL as my friends - but I found this post which shows how to call a CL program with parameters successfully...Not sure if it will help [^]
29 Jan 2013 by _Amy
AS400 is very old technology and I don't have much idea about it. But after searching I came across the following articles. You can check it. This may help you.http://www.netsplore.com/PublicPortal/Default.aspx?tabid=246[^]AS400 Data Connection in ASP.NET[^]--Amit
30 Jan 2013 by ujju.1
Got it. program.Invoke(true, ref parameters); invokes the program that we declare at appsettings (read connection from AS400Program(ConfigurationSettings.AppSettings["partsPricingConfig"]); )
15 Apr 2014 by kadu.sumit
How to call C Stored Procedure from C# code directly. There is a work around to call CSP from DB2 SP and call DB2 SP from .Net. But let me know if there is any direct option available. Thanks.
15 Apr 2014 by Sergey Alexandrovich Kryukov
Please see: http://support.microsoft.com/kb/310070[^].(I hope you are using ADO.NET, don't you?)—SA
15 Apr 2014 by Hussain Marzah
As I understand you have some code written in C and you want to call these functions from C# code.One way to do it is to build your C code as (.dll) then add that file to your C# references and call the functions you want.
16 Nov 2018 by Member 14056158
I'm writing a VB.Net application that needs to call a User Defined Table Function in DB2. The DB2 UDTF works correctly from a DB2 query but I can't figure out how to call it from VB.Net. I've attached a text document ( HereIsTheCode.txt ) of the VB.Net Function Definition I wrote to call the...
16 Nov 2018 by Member 14056158
I was using a production login in the connection but accessing a development database. The production credentials don't have an output queue defined for the development database so the .Net call (.ExecuteReader) to the DB2 UDTF was writing an error to some DB2/AS400 log and stalling. I found...
11 Sep 2014 by ricardo 30
i'm trying to make a simple login form with asp.net and db2 database ..but when i try to run it , in " Using db2Conn As New DB2Connection(Sconn.Stringkoneksi) " there is a error message " Invalid argument " ... why "Stringkoneksi" not read the connection string from sconn class ??btw ,...
19 Mar 2015 by jinesh sam
Hi Friends,I need to fetech some datafrom DB2 and paste in SQL. I am able to do that but some problem in date format. Date format in DB2 is like 2003-09-23 12:32:09.095499but when i insert into sql its became 9/23/2003 12:32:09 PMactually my DB2 field is a string not a date. but...
19 Mar 2015 by Joan Magnet
To fix it change .ToString() and format the string.Take a look at ustom Date and Time Format StringsI suppose you have declared this field as varchar instead of datetime in SQL database.
10 Apr 2014 by sivateja donthukurthi
i am trying to run a autofill textbox using db2 database it is running fine with sql server but how can i do it with ibmdb2the code is :aspx: ...
21 Oct 2013 by Member 10313090
create or replace PROCEDURE xyz_tbl_procasBEGIN execute immediate ' CREATE TABLE xyz ( empname varchar(10) )'; END;i want to write a stored procedure in db2 to create table.once i run this table is not getting...
21 Oct 2013 by Chintan Desai1988
create proc NewTable @TabName nvarchar(20),@Flag bit,@SID int,@Name varchar(20)asbeginif @Flag=1beginIF (EXISTS (SELECT * FROM INFORMATION_SCHEMA.TABLES WHERE TABLE_NAME = @TabName))BEGIN print 'hi'ENDelsebegin declare @str varchar(max) set @str='create table...
27 Jan 2012 by ssoni346
QUE:- A world have multiple forest, forest has multiple trees, and trees has different type of leafs and multiple leafs. Design DB Schema of this structure in fetch the all leafs where forestID=10??(Hint: use join)Plzzz help me...
27 Jan 2012 by OriginalGriff
This has the familiar odour of homework - so no code, just suggestions.What information do you need to store? Look at the objects you have, and list out what objects they are part of, or related to. Draw yourself a picture if you need to.Then look at how you store all that, with the...
27 Jan 2012 by Sander Rossel
Hint: Make your own homework... If we do it for you you won't learn anything from it, you might get a job and we'll have to work with people like you who can't solve their own problems.Worst case scenario: If we answer your question now we might have to work with your code/database in 10...
27 Jun 2019 by Member 12613458
G007 AFFILATES HOULD RETURN ALL DIRECT SUB AND SUB TO SUB LEVEL AFFILIATES. CAN BE TO NTH LEVEL HOW TO QUERY in DB2? AREVA_COMPANIES --------------------------- COMPANY_CODE|AFFILIATE_CODE G007 |K001 G007 |K002 G007 |K003 G007 |K004 K001 |K010 K001 ...
27 Jun 2019 by CHill60
Although UNION will work as you have demonstrated in your query, it is not extensible to the nth level. You essentially need to traverse a hierarchy - I have given an example here - Processing Loops in SQL Server[^] The example uses T-SQL which DB2 largely follows. It's been a long time since...
28 Oct 2013 by Member 9353131
How to fetch more than one rows using cursors in db2?I'm using cursor to fetch records from a table. Am just able to fetch only one row at a time. Need to fetch more than one records. Please help.CREATE or REPLACE PROCEDURE RTIMD.TicketDaemonProc (IN IN_RTIM_ID VARCHAR(50) default '', IN...
30 Oct 2013 by Member 9353131
CREATE or REPLACE PROCEDURE RTIMD.TicketDaemonProc (IN IN_RTIM_ID VARCHAR(50) default '', IN usr_name VARCHAR(20) DEFAULT '',IN api_method VARCHAR(50) DEFAULT '', IN params VARCHAR(2500) default '', IN application_name VARCHAR(20) default '', OUT V_OUT VARCHAR(2000))DYNAMIC RESULT SETS...
31 Mar 2015 by jinesh sam
Hi Friends,Please help me to get a comma seprated result. I am using DB2(IBM® Data Studio Version 4.1.0.0)Below is my querySELECT DISTINCT KEY_TMS FROM DBQPUBS.TCLT_BILL WHERE DT2_BILL = '2015-02-24';Updated Question I tried like thisSELECT CAST(LISTAGG(KEY_TMS ,',')AS...
30 Mar 2015 by CHill60
This largely depends on which version of DB2 you have available to you This solution uses LISTAGG[^] if you have DB2 9.7 FP4 or aboveIf you are using a version that supports variables you could try this[^] (yes I know it's SQL but it should work in DB2 as well)Or try this from Tom...
29 Oct 2020 by Virendra S from Bangalore, Karnataka
tblDepartmentMaster: IP Security Legal IOT employeee select his departments from a multi select dropdownlist. this departments details need to be stored in tblEmpMaster. how to manage this data in table tblEmpMaster(not yet designed). please...
29 Oct 2020 by CHill60
If an employee can be in multiple departments, don't store those details in the master table for the employee. Use a "link" table that connects the two ... e.g. create table tblDepartmentMaster ( deptId int identity(1,1), deptName...
26 Apr 2012 by Member 8631740
I'm trying to take the information the user types into these textboxes/drop down lists and stored them in my DB2 database. I believe we are having trouble with the CALL procedure and it keeps erroring at at Line 109: 'Execute the procedure.Line 110: ODC.ExecuteNonQuery()Line...
27 Apr 2012 by Kschuler
Your baddress and bcity sizes don't match between the parms and the procedure. You have 40-20 and 20-40.
26 Oct 2015 by sudevsu
Hello Experts,I have simple question yet confusing(for me)...I have a table which results after grabbing a select statement on that table are as follows select * from VINBINI where BABLOC='AE084' BAITEM BABLOC BAQOHDU266004817 AE084 ...
26 Oct 2015 by Tim Carmichael
You didn't provide an example of a BABLOC that doesn't have a shared bin, so anything that follow is just a guess.select BABLOC, Shared_Bin = case when BinUse > 1 then "Yes" else "No"from (select BABLOC, BinUse = count(BAITEM) from VINBINIgroup by BABLOC) dt
27 Oct 2015 by Zoltán Zörgő
I don't know DB2, but in MySql you can do seomething like this:select babloc,if( (select count(distinct left(BAITEM,2)) from VINBINI i where i.BABLOC = e.BABLOC) > 1, "yes", "no") as SHARED_BINfrom VINBINI egroup by BABLOCSee: http://sqlfiddle.com/#!9/21716/8[^]I don't...
10 Dec 2017 by Member 13568694
Ever issues showing my gmail account and password showing invalid when login.
3 Jul 2015 by jinesh sam
Hi friends,i need to fetch distinct KEY_ACCT from the table TPOS_INTRA criteria is 1) The account which have NUM_ACCT_TYPE both 0 and 12) while selecting keep in mind both KEY_ACCT,CDE_MSDW_SEC values are sameKEY_ACCT NUM_ACCT_TYPE CDE_MSDW_SEC...
2 Jul 2015 by Jitesh Hirani
Please try thisSELECT A.KEY_ACCT, A.NUM_ACCT_TYPE, A.CDE_MSDW_SECFROM DBQPEDB.TPOS_INTRA A with (NOLOCK) where A.CDE_MSDW_SEC in( SELECT B.CDE_MSDW_SEC FROM DBQPEDB.TPOS_INTRA B with (NOLOCK) where B.NUM_ACCT_TYPE = '1') and A.NUM_ACCT_TYPE = '0'
10 Oct 2017 by Member 13456434
i need to create 2 tables for below data how to map between the data values.As my data values are each of them are not unique cover_id , file , TestCase 256 , /x/eng/rlse/DOT//prod/common/raidv2/ric.c , test1 469 , ...
10 Oct 2017 by OriginalGriff
Create two tables Table1: CoverID INT Filepath NVARCHAR TestCaseID INT, foreign key to Table2 Table2: ID INT, IDENTITY caseName NVARCHAR
24 May 2013 by Ashok26
I have a .NET application using DB2 provider(refers to IBM.Data.DB2.dll).What do I need to install for DB2 in order to run this application.I do not want to install complete DB2 client which will for sure install data provider for .NET.
26 Oct 2015 by sudevsu
Hello Experts,If PRM_QTY value is null then it should execure certain part of query other if should check for this condition in sotred procedureSeems pretty simple but I don't know why this is not working. ALTER SPECIFIC PROCEDURE R34FILES.HBINCONRAC REPLACE (IN PRMLOC CHARACTER (2)...
26 Oct 2015 by George Jonsson
Instead of IF PRM_QTY IS NULLtry the built in functionIF isnull(PRM_QTY) THENSee MYSQL: ISNULL FUNCTION[^]And don't forget the THEN in the IF statement.[UPDATE]You could also try the ifnull function.SET PRM_QTY = ifnull(PRM_QTY, NULL);or, as you convert to an integer...
14 Jul 2013 by shakilajannat
How to insert data in Db2 database using store procedure with Vb6 For i = 1 To lvwDatalist.ListItems.Count If Trim(lvwDatalist.ListItems(i).Text) = "" Then Exit For With oCmd .Parameters.Refresh .ActiveConnection = cnAP ...
14 Jul 2013 by Mehdi Gholam
Check your table DB2ADMIN.MISYS_ACTSTAT, there might be required columns in that.
23 Jul 2013 by shakilajannat
Private Sub cmdTransfer_DB2_Click(Index As Integer) On Error GoTo Err_Des Dim Cmd As New ADODB.Command Dim Param As New ADODB.Parameter Dim res As Integer ProBar.Visible = True ProBar.Min = 0 ProBar.Max = lvwDatalist.ListItems.Count ProBar.Value...