Click here to Skip to main content
15,887,596 members

Welcome to the Lounge

   

For discussing anything related to a software developer's life but is not for programming questions. Got a programming question?

The Lounge is rated Safe For Work. If you're about to post something inappropriate for a shared office environment, then don't post it. No ads, no abuse, and no programming questions. Trolling, (political, climate, religious or whatever) will result in your account being removed.

 
GeneralRe: Christmas Trees Confuse Me Pin
Daniel Pfeffer19-Dec-23 19:50
professionalDaniel Pfeffer19-Dec-23 19:50 
GeneralRe: Christmas Trees Confuse Me Pin
Alister Morton1-Jan-24 23:38
Alister Morton1-Jan-24 23:38 
GeneralRe: Christmas Trees Confuse Me Pin
Peter Adam19-Dec-23 21:35
professionalPeter Adam19-Dec-23 21:35 
GeneralRe: Christmas Trees Confuse Me Pin
Steve Raw20-Dec-23 6:44
professionalSteve Raw20-Dec-23 6:44 
GeneralRe: Christmas Trees Confuse Me Pin
trønderen20-Dec-23 8:28
trønderen20-Dec-23 8:28 
GeneralRe: Christmas Trees Confuse Me Pin
Rob Philpott20-Dec-23 22:10
Rob Philpott20-Dec-23 22:10 
GeneralRe: Christmas Trees Confuse Me Pin
Steve Raw20-Dec-23 22:40
professionalSteve Raw20-Dec-23 22:40 
GeneralRe: Christmas Trees Confuse Me Pin
trønderen21-Dec-23 1:43
trønderen21-Dec-23 1:43 
Most of Norway uses a power distribution system called "IT", Isolated Terra (i.e. ground), rather than "TN", Terra and Neutral. IT is "delta" 3-phase: There is no neutral; you'll find 230V between two triangle corners. TN uses "star" 3-phase, with 230V from a corner to a center neutral, 400V between triangle corners.

With IT, the two pins giving you 230V is supposed to be symmetric around ground potential (otherwise you have a ground problem that should be fixed). So e.g. if one of the conductors shortcut to the shield of the apparatus, you touch it and ground at the same time, you will experience roughly half the voltage. To get a 230V shock, you would have to touch both conductors at the same time, before the fuse blows.

In a TN system, you will have a 230V blow if you touch any conductor, and you are grounded. If you touch two corners of the star, i.e. two live conductors on different phases, you get a 400V blow.

Several times I have tried to make power supply people explain to me what is so great about TN, what's in it for me as a consumer. They invariably come up with a lot of advantages as seen from the power station, things that I do not see as a consumer. I am currently on an IT network, and I see no reason to fight for an "upgrade" to TN. (It won't happen anyway, as it would require all new cabling: IT manages with 3 conductors, TN requires 4 or 5, depending on whether you want a separate ground conductor.

The only issue with IT is for those who want to install a fast 3-phase charger for their electric cars. Very few cars have onboard chargers that can handle 3*230V, almost all are for 3*400V. As I do not yet have an electric car, it doesn't matter much. Besides, an 11 or 22 kW single-phase charger is fast enough for me (with less wear on the batteries). I much prefer a lower shock in case of a short circuit somewhere.
GeneralRe: Christmas Trees Confuse Me Pin
jschell21-Dec-23 5:09
jschell21-Dec-23 5:09 
GeneralRe: Christmas Trees Confuse Me Pin
Alister Morton1-Jan-24 23:40
Alister Morton1-Jan-24 23:40 
GeneralRe: Christmas Trees Confuse Me Pin
Roger Wright19-Dec-23 2:56
professionalRoger Wright19-Dec-23 2:56 
GeneralRe: Christmas Trees Confuse Me Pin
PIEBALDconsult19-Dec-23 3:47
mvePIEBALDconsult19-Dec-23 3:47 
GeneralRe: Christmas Trees Confuse Me Pin
Rich Shealer19-Dec-23 4:52
Rich Shealer19-Dec-23 4:52 
GeneralRe: Christmas Trees Confuse Me Pin
jschell19-Dec-23 5:20
jschell19-Dec-23 5:20 
GeneralRe: Christmas Trees Confuse Me Pin
Paul Sanders (the other one)19-Dec-23 23:03
Paul Sanders (the other one)19-Dec-23 23:03 
GeneralRe: Christmas Trees Confuse Me Pin
JohaViss6119-Dec-23 23:39
professionalJohaViss6119-Dec-23 23:39 
GeneralRe: Christmas Trees Confuse Me Pin
Member 1330167920-Dec-23 0:04
Member 1330167920-Dec-23 0:04 
GeneralRe: Christmas Trees Confuse Me Pin
trønderen20-Dec-23 1:18
trønderen20-Dec-23 1:18 
GeneralRe: Christmas Trees Confuse Me Pin
WPerkins20-Dec-23 3:38
WPerkins20-Dec-23 3:38 
GeneralRe: Christmas Trees Confuse Me Pin
Kent K20-Dec-23 4:13
professionalKent K20-Dec-23 4:13 
GeneralRe: Christmas Trees Confuse Me Pin
MSBassSinger20-Dec-23 5:43
professionalMSBassSinger20-Dec-23 5:43 
GeneralRe: Christmas Trees Confuse Me Pin
antonelloa20-Dec-23 10:52
antonelloa20-Dec-23 10:52 
GeneralRe: Christmas Trees Confuse Me Pin
jkirkerx20-Dec-23 7:52
professionaljkirkerx20-Dec-23 7:52 
GeneralRe: Christmas Trees Confuse Me Pin
trønderen20-Dec-23 10:56
trønderen20-Dec-23 10:56 
GeneralRe: Christmas Trees Confuse Me Pin
jkirkerx20-Dec-23 11:40
professionaljkirkerx20-Dec-23 11:40 

General General    News News    Suggestion Suggestion    Question Question    Bug Bug    Answer Answer    Joke Joke    Praise Praise    Rant Rant    Admin Admin   

Use Ctrl+Left/Right to switch messages, Ctrl+Up/Down to switch threads, Ctrl+Shift+Left/Right to switch pages.